ieee1394: sbp2: don't prefer MODE SENSE 10
authorStefan Richter <stefanr@s5r6.in-berlin.de>
Wed, 6 Sep 2006 23:06:00 +0000 (01:06 +0200)
committerStefan Richter <stefanr@s5r6.in-berlin.de>
Sun, 17 Sep 2006 17:38:52 +0000 (19:38 +0200)
commit98e238cd42be6c0852da519303cf0182690f8d9f
tree8e9aab3bf39d6194bd9009e36586535887ff139d
parenta1842be898a2295ef513ed0a5d26f65d6283cb11
ieee1394: sbp2: don't prefer MODE SENSE 10

In the old days, sbp2 used to coerce all MODE SENSE commands into the
10 bytes version.  When all command set conversions were removed from
sbp2 several months ago, sdev->use_10_for_ms = 1 was added.  Meaning,
higher SCSI layers preferred the 10 bytes version but would try the 6
bytes version if the former failed.

Recently, a problem with the 10 bytes version was discovered.  An Initio
INIC-1530 firmware accepted the 10 bytes version but replied with bogus
data, showing the HDD incorrectly as write-protected.  Since RBC
actually mandates MODE SENSE (6), I checked which version was sent by
Windows XP and Mac OS X 10.3 to an SBP-2 target hosted by Linux --- it
was the 6 bytes version.  (Exception: OS X sent the 10 bytes version to
an MMC target.  RBC and SBC got MODE SENSE (6).)

Therefore, drop the use_10_for_ms flag from sbp2.  Now the upper layers
will try MODE SENSE (6) before MODE SENSE (10) on all SBP-2 devices.

Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>
drivers/ieee1394/sbp2.c