]> pilppa.com Git - linux-2.6-omap-h63xx.git/commitdiff
ibmpex: report temperatures in mC, not C
authorDarrick J. Wong <djwong@us.ibm.com>
Thu, 20 Mar 2008 00:00:48 +0000 (17:00 -0700)
committerLinus Torvalds <torvalds@linux-foundation.org>
Thu, 20 Mar 2008 01:53:36 +0000 (18:53 -0700)
ibmpex's temperature sensors report incorrect units.  Apply a conversion
factor so that tempertures report correctly.  Until now, no systems seemed to
report temperatures this way, but evidently QS2x blades do.

Signed-off-by: Darrick J. Wong <djwong@us.ibm.com>
Cc: "Mark M. Hoffman" <mhoffman@lightlink.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
drivers/hwmon/ibmpex.c

index db551d869feb31e64663366ef0d5e0fed27eaf25..4e9b19c6732fefb22012e94b324b32eb02a5024a 100644 (file)
@@ -410,7 +410,7 @@ static int ibmpex_find_sensors(struct ibmpex_bmc_data *data)
                        sensor_type = TEMP_SENSOR;
                        num_temp++;
                        sensor_counter = num_temp;
-                       data->sensors[i].multiplier = 1;
+                       data->sensors[i].multiplier = 1000;
                } else
                        continue;