ACPI: thinkpad-acpi: make sure DSDT TMPx readings don't return +128
authorHenrique de Moraes Holschuh <hmh@hmh.eng.br>
Thu, 19 Jul 2007 02:45:45 +0000 (23:45 -0300)
committerLen Brown <len.brown@intel.com>
Sun, 22 Jul 2007 03:49:55 +0000 (23:49 -0400)
We get +128 instead of -128 from the DSDT TMPx methods, due to errors when
converting a EC byte return that is a s8 to an ACPI handler return that is
an int.

Fix it once and for all, by clamping acceptable temperature readings from
DSDT TMPx so that anything outside the [-127,+127] range is converted to
TP_EC_THERMAL_TMP_NA (-128).

Signed-off-by: Henrique de Moraes Holschuh <hmh@hmh.eng.br>
Cc: Michael Olbrich <michael.olbrich@gmx.net>
Signed-off-by: Len Brown <len.brown@intel.com>
drivers/misc/thinkpad_acpi.c

index 623d36fd8dbeba215a78a35e4a4e4dac66200656..f74d7d600d83c94aa04cb26c95899370f82d026d 100644 (file)
@@ -2853,6 +2853,8 @@ static int thermal_get_sensor(int idx, s32 *value)
                        snprintf(tmpi, sizeof(tmpi), "TMP%c", '0' + idx);
                        if (!acpi_evalf(ec_handle, &t, tmpi, "d"))
                                return -EIO;
+                       if (t > 127 || t < -127)
+                               t = TP_EC_THERMAL_TMP_NA;
                        *value = t * 1000;
                        return 0;
                }