x86: hpet: workaround SB700 BIOS
authorThomas Gleixner <tglx@linutronix.de>
Thu, 14 Aug 2008 10:17:06 +0000 (12:17 +0200)
committerThomas Gleixner <tglx@linutronix.de>
Thu, 14 Aug 2008 11:23:45 +0000 (13:23 +0200)
AMD SB700 based systems with spread spectrum enabled use a SMM based
HPET emulation to provide proper frequency setting. The SMM code is
initialized with the first HPET register access and takes some time to
complete. During this time the config register reads 0xffffffff. We
check for max. 1000 loops whether the config register reads a non
0xffffffff value to make sure that HPET is up and running before we go
further. A counting loop is safe, as the HPET access takes thousands
of CPU cycles. On non SB700 based machines this check is only done
once and has no side effects.

Based on a quirk patch from: crane cai <crane.cai@amd.com>

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
arch/x86/kernel/hpet.c

index ad2b15a1334d919419b9040b52c2062dd5d3666d..59fd3b6b13036e1e279e54d0e1e3d3f5ebb55166 100644 (file)
@@ -359,6 +359,7 @@ static int hpet_clocksource_register(void)
 int __init hpet_enable(void)
 {
        unsigned long id;
+       int i;
 
        if (!is_hpet_capable())
                return 0;
@@ -369,6 +370,29 @@ int __init hpet_enable(void)
         * Read the period and check for a sane value:
         */
        hpet_period = hpet_readl(HPET_PERIOD);
+
+       /*
+        * AMD SB700 based systems with spread spectrum enabled use a
+        * SMM based HPET emulation to provide proper frequency
+        * setting. The SMM code is initialized with the first HPET
+        * register access and takes some time to complete. During
+        * this time the config register reads 0xffffffff. We check
+        * for max. 1000 loops whether the config register reads a non
+        * 0xffffffff value to make sure that HPET is up and running
+        * before we go further. A counting loop is safe, as the HPET
+        * access takes thousands of CPU cycles. On non SB700 based
+        * machines this check is only done once and has no side
+        * effects.
+        */
+       for (i = 0; hpet_readl(HPET_CFG) == 0xFFFFFFFF; i++) {
+               if (i == 1000) {
+                       printk(KERN_WARNING
+                              "HPET config register value = 0xFFFFFFFF. "
+                              "Disabling HPET\n");
+                       goto out_nohpet;
+               }
+       }
+
        if (hpet_period < HPET_MIN_PERIOD || hpet_period > HPET_MAX_PERIOD)