-static int __init is_l2_writethrough(void)
+static void __init kirkwood_l2_init(void)
{
- return !!(readl(L2_CONFIG_REG) & L2_WRITETHROUGH);
+#ifdef CONFIG_CACHE_FEROCEON_L2_WRITETHROUGH
+ writel(readl(L2_CONFIG_REG) | L2_WRITETHROUGH, L2_CONFIG_REG);
+ feroceon_l2_init(1);
+#else
+ writel(readl(L2_CONFIG_REG) & ~L2_WRITETHROUGH, L2_CONFIG_REG);
+ feroceon_l2_init(0);
+#endif
}
void __init kirkwood_init(void)
kirkwood_setup_cpu_mbus();
#ifdef CONFIG_CACHE_FEROCEON_L2
- feroceon_l2_init(is_l2_writethrough());
+ kirkwood_l2_init();
#endif
}
help
This option enables the Feroceon L2 cache controller.
+config CACHE_FEROCEON_L2_WRITETHROUGH
+ bool "Force Feroceon L2 cache write through"
+ depends on CACHE_FEROCEON_L2
+ default n
+ help
+ Say Y here to use the Feroceon L2 cache in writethrough mode.
+ Unless you specifically require this, say N for writeback mode.
+
config CACHE_L2X0
bool "Enable the L2x0 outer cache controller"
depends on REALVIEW_EB_ARM11MP || MACH_REALVIEW_PB11MP || MACH_REALVIEW_PB1176
msr cpsr_c, ip
bl feroceon_flush_kern_cache_all
-#if defined(CONFIG_CACHE_FEROCEON_L2) && !defined(CONFIG_L2_CACHE_WRITETHROUGH)
+#if defined(CONFIG_CACHE_FEROCEON_L2) && \
+ !defined(CONFIG_CACHE_FEROCEON_L2_WRITETHROUGH)
mov r0, #0
mcr p15, 1, r0, c15, c9, 0 @ clean L2
mcr p15, 0, r0, c7, c10, 4 @ drain WB
.align 5
ENTRY(cpu_feroceon_dcache_clean_area)
-#if defined(CONFIG_CACHE_FEROCEON_L2) && !defined(CONFIG_L2_CACHE_WRITETHROUGH)
+#if defined(CONFIG_CACHE_FEROCEON_L2) && \
+ !defined(CONFIG_CACHE_FEROCEON_L2_WRITETHROUGH)
mov r2, r0
mov r3, r1
#endif
add r0, r0, #CACHE_DLINESIZE
subs r1, r1, #CACHE_DLINESIZE
bhi 1b
-#if defined(CONFIG_CACHE_FEROCEON_L2) && !defined(CONFIG_L2_CACHE_WRITETHROUGH)
+#if defined(CONFIG_CACHE_FEROCEON_L2) && \
+ !defined(CONFIG_CACHE_FEROCEON_L2_WRITETHROUGH)
1: mcr p15, 1, r2, c15, c9, 1 @ clean L2 entry
add r2, r2, #CACHE_DLINESIZE
subs r3, r3, #CACHE_DLINESIZE
str r2, [r0] @ hardware version
mov r0, r0
mcr p15, 0, r0, c7, c10, 1 @ clean D entry
-#if defined(CONFIG_CACHE_FEROCEON_L2) && !defined(CONFIG_L2_CACHE_WRITETHROUGH)
+#if defined(CONFIG_CACHE_FEROCEON_L2) && \
+ !defined(CONFIG_CACHE_FEROCEON_L2_WRITETHROUGH)
mcr p15, 1, r0, c15, c9, 1 @ clean L2 entry
#endif
mcr p15, 0, r0, c7, c10, 4 @ drain WB