]> pilppa.com Git - linux-2.6-omap-h63xx.git/commitdiff
powerpc/cell/axon-msi: Fix MSI after kexec
authorArnd Bergmann <arnd@arndb.de>
Fri, 12 Dec 2008 09:19:50 +0000 (09:19 +0000)
committerPaul Mackerras <paulus@samba.org>
Tue, 16 Dec 2008 02:48:18 +0000 (13:48 +1100)
Commit d015fe995 'powerpc/cell/axon-msi: Retry on missing interrupt'
has turned a rare failure to kexec on QS22 into a reproducible
error, which we have now analysed.

The problem is that after a kexec, the MSIC hardware still points
into the middle of the old ring buffer.  We set up the ring buffer
during reboot, but not the offset into it.  On older kernels, this
would cause a storm of thousands of spurious interrupts after a
kexec, which would most of the time get dropped silently.

With the new code, we time out on each interrupt, waiting for
it to become valid.  If more interrupts come in that we time
out on, this goes on indefinitely, which eventually leads to
a hard crash.

The solution in this commit is to read the current offset from
the MSIC when reinitializing it.  This now works correctly, as
expected.

Reported-by: Dirk Herrendoerfer <d.herrendoerfer@de.ibm.com>
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Michael Ellerman <michael@ellerman.id.au>
Signed-off-by: Paul Mackerras <paulus@samba.org>
arch/powerpc/platforms/cell/axon_msi.c

index 442cf36aa172920b355710e65a68624d43293d33..0ce45c2b42f8eb67a1ea5156fcf476bdb3f3924a 100644 (file)
@@ -413,6 +413,9 @@ static int axon_msi_probe(struct of_device *device,
                        MSIC_CTRL_IRQ_ENABLE | MSIC_CTRL_ENABLE |
                        MSIC_CTRL_FIFO_SIZE);
 
+       msic->read_offset = dcr_read(msic->dcr_host, MSIC_WRITE_OFFSET_REG)
+                               & MSIC_FIFO_SIZE_MASK;
+
        device->dev.platform_data = msic;
 
        ppc_md.setup_msi_irqs = axon_msi_setup_msi_irqs;